Waveguide Y Branch (Y) is a Y-shaped optical waveguide branch that can split one path into two or combine two paths into one. Power distribution among the arms is determined by the coupling strength, which can be given directly by a coupling coefficient or converted from a cross-over length. It is suitable for power splitting/combining, feeding the two arms of an interferometer, and tree-like distribution networks.

Ports

Three bidirectional optical signal ports: one common port and two branch arms. The table shows the default configuration.

Name Type Data
port 1 Optical Signal Bidirectional
port 2 Optical Signal Bidirectional
port 3 Optical Signal Bidirectional

After changing configuration, the port directions may change.

Properties

General

Used to identify and manage the element itself, including name, annotation, enabled state, and display. This group of properties only affects schematic presentation and does not change device behavior.

Name Description Default value Default unit Range
name Element name Y_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether the element is enabled true - [true, false]
type Unique type identifier of the element Waveguide Y Branch - -
description Brief description of the element Optical waveguide branch - -
prefix Prefix for the element name Y - -
local path Local path or working folder of the element - - -

Standard

Defines the branch operating mode and how the power-splitting ratio is specified.

Name Description Default value Default unit Range
configuration Port configuration bidirectional - [bidirectional, splitter, combiner]
insertion loss Insertion loss 0 dB [0, +∞)
input parameter How the coupling coefficient is specified coupling coefficient - [coupling coefficient, length]
length Length 0 m [0, +∞)

Waveguide

Sets the additional phase shift introduced by the branch for adjusting the relative phase between the two arms.

Name Description Default value Default unit Range
phase shift Phase shift 0 rad (-∞, +∞)

Waveguide / Mode 1

Sets the power-splitting ratio of mode 1 (typically TE), which determines the power distribution between the two arms for that mode.

Name Description Default value Default unit Range
orthogonal identifier 1 Orthogonal identifier of mode 1 1 - [1, +∞)
label 1 Label of mode 1 TE - -
coupling coefficient 1 Coupling coefficient 1 0.5 - [0, 1]
cross over length 1 Cross-over length of mode 1 0 m [0, +∞)

Waveguide / Mode 2

Sets the power-splitting ratio of mode 2 (typically TM), which determines the power distribution between the two arms for that mode.

Name Description Default value Default unit Range
orthogonal identifier 2 Orthogonal identifier of mode 2 2 - [1, +∞)
label 2 Label of mode 2 TM - -
coupling coefficient 2 Coupling coefficient 2 0.5 - [0, 1]
cross over length 2 Cross-over length of mode 2 0 m [0, +∞)

Diagnostic

Used to check the deviation between the ideal response and the digital-filter fit to confirm frequency-domain accuracy in time-domain simulation. Keep disabled for routine simulation.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)

Results

When run diagnostic is enabled, time-domain sampled simulation produces the following results for response verification:

Results

diagnostic/response

Name Description
transmission Complex transmittance of the ideal and fitted responses versus frequency.
gain Gain (dB) of the ideal and fitted responses versus frequency.
error Relative mean-square error between the ideal and fitted amplitudes.

The response number corresponds to a pair of input port, output port, and mode.