Waveguide Coupler

Waveguide Coupler

C

Waveguide Coupler (C) describes directional coupling that occurs when two waveguides are brought close together: after light enters the coupling region, it is redistributed between the two waveguides according to the coupling strength. Coupling strength can be specified directly by a coupling coefficient, converted from a cross-over length, or given by a frequency-dependent coupling-coefficient table; orthogonal modes such as TE and TM can be set independently. It is a fundamental element for splitting and combining, Mach–Zehnder interferometers, ring-resonator external coupling, and switch networks.

Ports

Four bidirectional optical signal ports forming a 2×2 coupler. The table reflects the default configuration.

Name Type Data
port 1 Optical Signal Bidirectional
port 2 Optical Signal Bidirectional
port 3 Optical Signal Bidirectional
port 4 Optical Signal Bidirectional

After changing configuration, port directions may change.

Properties

General

Identifies and manages the element itself, including name, annotation, enable state, and display style. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name C_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether the element is enabled true - [true, false]
type Unique type identifier of the element Waveguide Coupler - -
description Brief description of the element Optical waveguide coupler - -
prefix Prefix for the element name C - -
local path Local path or working folder of the element - - -

Standard

Selects the optical propagation direction, determining whether light can pass in one direction only.

Name Description Default value Default unit Range
configuration Port configuration bidirectional - [bidirectional, unidirectional]

Waveguide

Sets common parameters of the coupling region, determining how coupling strength is described and the device excess loss.

Name Description Default value Default unit Range
insertion loss Insertion loss 0 dB [0, +∞)
input parameter Input method for the coupling coefficient coupling coefficient - [coupling coefficient, length, table]
length Length 0 m [0, +∞)
load from file Whether to load data from a file false - [true, false]
conjugate Whether to take the conjugate false - [true, false]

Waveguide / Mode 1

Sets the coupling strength of mode 1 (typically TE), which determines the power-splitting ratio between the two paths for that mode.

Name Description Default value Default unit Range
orthogonal identifier 1 Orthogonal identifier of mode 1 1 - [1, +∞)
label 1 Label of mode 1 TE - -
coupling coefficient 1 Coupling coefficient 1 0.5 - [0, 1]
cross over length 1 Cross-over length of mode 1 1 m [0, +∞)
measurement filename 1 Measurement data file name 1 - - -
coupling coefficients 1 Coupling coefficient set of mode 1 1×2; columns: frequency (Hz), coupling coefficient; first row [1.931e14, 0.5] - -

Waveguide / Mode 2

Sets the coupling strength of mode 2 (typically TM), used to describe the polarization-dependent power-splitting ratio.

Name Description Default value Default unit Range
orthogonal identifier 2 Orthogonal identifier of mode 2 2 - [1, +∞)
label 2 Label of mode 2 TM - -
coupling coefficient 2 Coupling coefficient 2 0.5 - [0, 1]
cross over length 2 Cross-over length of mode 2 1 m [0, +∞)
measurement filename 2 Measurement data file name 2 - - -
coupling coefficients 2 Coupling coefficient set of mode 2 1×2; columns: frequency (Hz), coupling coefficient; first row [1.931e14, 0.5] - -

Numerical / Digital Filter

Fits the device frequency-domain response to a digital filter required for time-domain simulation.

Name Description Default value Default unit Range
single tap filter Whether to use a single-tap filter false - [true, false]
number of taps estimation Tap-count estimation method fit tolerance - [disabled, fit tolerance, group delay]
filter fit tolerance Filter fit tolerance 0.001 - (0, 1)
window function Window function rectangular - [rectangular, hamming, hanning]
number of fir taps Number of FIR taps 256 - [1, +∞)
maximum number of fir taps Upper limit on the number of FIR taps 4096 - [1, +∞)
filter delay Filter delay 0 s [0, +∞)
initialize filter taps Whether to initialize filter taps false - [true, false]

Diagnostic

Used to check the deviation between the ideal response and the digital-filter fit, confirming the frequency-domain accuracy of time-domain simulation. Keep disabled for routine simulations.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)

Results

When run diagnostic is enabled, time-domain sample-mode simulation produces the following results for verifying the response:

Results

diagnostic/response

Name Description
transmission Complex transmittance versus frequency for the ideal and fitted responses.
gain Gain (dB) versus frequency for the ideal and fitted responses.
error Relative mean-square error between the ideal and fitted magnitudes.

The response number corresponds to a pair of input port, output port, and mode.