Waveguide Crossing
Waveguide Crossing #
![]()
Waveguide Crossing (WX) describes the transmission behavior when two waveguides cross in the same plane: the main optical path continues straight in the original direction, while a portion of the light is reflected or leaks into the crossing waveguide. Crossings are hard to avoid in high-density photonic routing; this element is used to evaluate the insertion loss and channel crosstalk they introduce.
Ports #
Four bidirectional optical signal ports forming a crossing. The table reflects the default configuration.
| Name | Type | Data |
|---|---|---|
| port 1 | Optical Signal | Bidirectional |
| port 2 | Optical Signal | Bidirectional |
| port 3 | Optical Signal | Bidirectional |
| port 4 | Optical Signal | Bidirectional |
After changing configuration, port directions may change.
Properties #
General #
Identifies and manages the element itself, including name, annotation, enable state, and display style. This property group affects schematic presentation only and does not change device behavior.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| name | Element name | WX_1 | - | - |
| annotate | Whether to show annotation | true | - | [true, false] |
| enabled | Whether the element is enabled | true | - | [true, false] |
| type | Unique type identifier of the element | Waveguide Crossing | - | - |
| description | Brief description of the element | Optical waveguide crossing | - | - |
| prefix | Prefix for the element name | WX | - | - |
| local path | Local path or working folder of the element | - | - | - |
Standard #
Selects the optical propagation direction, determining whether light can pass in one direction only.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| configuration | Port configuration | bidirectional | - | [bidirectional, unidirectional] |
Waveguide / Mode 1 #
Sets the power distribution of mode 1 (typically TE), used to describe polarization-dependent crossing loss and crosstalk.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| orthogonal identifier 1 | Orthogonal identifier of mode 1 | 1 | - | [1, +∞) |
| label 1 | Label of mode 1 | TE | - | - |
| transmission 1 | Transmission of mode 1 | 1 | - | [0, 1] |
| reflection 1 | Reflection of mode 1 | 0 | - | [0, 1] |
| cross talk 1 | Crosstalk of mode 1 | 0 | - | [0, 0.5] |
| crosstalk phase 1 | Crosstalk phase of mode 1 | π/2 | rad | (-∞, +∞) |
Waveguide / Mode 2 #
Sets the power distribution of mode 2 (typically TM), used to describe polarization-dependent crossing loss and crosstalk.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| orthogonal identifier 2 | Orthogonal identifier of mode 2 | 2 | - | [1, +∞) |
| label 2 | Label of mode 2 | TM | - | - |
| transmission 2 | Transmission of mode 2 | 1 | - | [0, 1] |
| reflection 2 | Reflection of mode 2 | 0 | - | [0, 1] |
| cross talk 2 | Crosstalk of mode 2 | 0 | - | [0, 0.5] |
| crosstalk phase 2 | Crosstalk phase of mode 2 | π/2 | rad | (-∞, +∞) |
Diagnostic #
Used to check the deviation between the ideal response and the digital-filter fit, confirming the frequency-domain accuracy of time-domain simulation. Keep disabled for routine simulations.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| run diagnostic | Whether to run diagnostics | false | - | [true, false] |
| diagnostic size | Number of diagnostic data points or buffer size | 1024 | - | - |
Results #
When run diagnostic is enabled, time-domain sample-mode simulation produces the following results for verifying the response:
![]()
diagnostic/response
| Name | Description |
|---|---|
| transmission | Complex transmittance versus frequency for the ideal and fitted responses. |
| gain | Gain (dB) versus frequency for the ideal and fitted responses. |
| error | Relative mean-square error between the ideal and fitted magnitudes. |
The response number corresponds to a pair of input port, output port, and mode.