Waveguide Arc Bend
Waveguide Arc Bend #
![]()
Waveguide Arc Bend (WGD) is a waveguide segment with constant bend radius, used to change optical path direction or form the curved portion of ring structures. Smaller bend radii make radiation loss and mode mismatch more significant. Arc length is determined jointly by radius and central angle, and can be used to evaluate bend loss and optimize layout compactness.
Ports #
Two optical signal ports, one at each end of the bend segment. Bidirectional by default; can also be switched to unidirectional.
| Name | Type | Data |
|---|---|---|
| port 1 | Optical Signal | Bidirectional |
| port 2 | Optical Signal | Bidirectional |
The table reflects the default bidirectional configuration; after changing configuration, port directions may change.
Properties #
General #
Identifies and manages the element itself, including name, annotation, enable state, and display style. This property group affects schematic presentation only and does not change device behavior.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| name | Element name | WGD_1 | - | - |
| annotate | Whether to show annotation | true | - | [true, false] |
| enabled | Whether the element is enabled | true | - | [true, false] |
| type | Unique type identifier of the element | Waveguide Arc Bend | - | - |
| description | Brief description of the element | The model of a constant bending radius waveguide | - | - |
| prefix | Prefix for the element name | WGD | - | - |
| local path | Local path or working folder of the element | - | - | - |
Standard #
Defines the geometry and operating frequency of the bend segment, which determine the turning angle and bend loss.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| configuration | Port configuration | bidirectional | - | [bidirectional, unidirectional] |
| frequency | Frequency | 193.1 | THz | (0, +∞) |
| angle | Angle | 0 | rad | (-∞, +∞) |
| radius | Radius | 0 | m | (0, +∞) |
Waveguide / Mode 1 #
Sets the transmission parameters of mode 1 (typically TE) in the bend segment, including excess loss, phase accumulation, and dispersion.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| orthogonal identifier 1 | Orthogonal identifier of mode 1 | 1 | - | [1, +∞) |
| label 1 | Label of mode 1 | TE | - | - |
| loss 1 | Loss of mode 1 | 0 | dB | [0, +∞) |
| effective index 1 | Effective index of mode 1 | 1 | - | (-∞, +∞) |
| group index 1 | Group index of mode 1 | 1 | - | [0, +∞) |
| dispersion 1 | Dispersion of mode 1 | 0 | s/m/m | (-∞, +∞) |
| dispersion slope 1 | Dispersion slope of mode 1 | 0 | s/m^2/m | (-∞, +∞) |
Waveguide / Mode 1 / Thermal #
Sets the temperature coefficients of mode 1, describing how temperature changes affect refractive index and loss.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| effective index temperature sensitivity 1 | Temperature sensitivity of the effective index of mode 1 | 0 | /K | (-∞, +∞) |
| excess loss temperature sensitivity 1 | Temperature sensitivity of the excess loss of mode 1 | 0 | /K | [0, +∞) |
Waveguide / Mode 2 #
Sets the transmission parameters of mode 2 (typically TM) in the bend segment, used to describe polarization-dependent bend loss.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| orthogonal identifier 2 | Orthogonal identifier of mode 2 | 2 | - | [1, +∞) |
| label 2 | Label of mode 2 | TM | - | - |
| loss 2 | Loss of mode 2 | 0 | dB | [0, +∞) |
| effective index 2 | Effective index of mode 2 | 1 | - | (-∞, +∞) |
| group index 2 | Group index of mode 2 | 1 | - | [0, +∞) |
| dispersion 2 | Dispersion of mode 2 | 0 | s/m/m | (-∞, +∞) |
| dispersion slope 2 | Dispersion slope of mode 2 | 0 | s/m^2/m | (-∞, +∞) |
Waveguide / Mode 2 / Thermal #
Sets the temperature coefficients of mode 2; the role is the same as for mode 1.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| effective index temperature sensitivity 2 | Temperature sensitivity of the effective index of mode 2 | 0 | /K | (-∞, +∞) |
| excess loss temperature sensitivity 2 | Temperature sensitivity of the excess loss of mode 2 | 0 | /K | [0, +∞) |
Thermal #
Controls whether thermal effects are enabled, and specifies the operating temperature and the fraction of waveguide length affected by heating.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| thermal effects | Whether to enable thermal effects | false | - | [true, false] |
| temperature | Temperature | %temperature% |
K | (-∞, +∞) |
| nominal temperature | Nominal temperature | 300 | K | (-∞, +∞) |
| thermal fill factor | Fraction of waveguide length affected by thermal effects | 1 | - | [0, 1] |
Numerical / Digital Filter #
Fits the device frequency-domain response to a digital filter required for time-domain simulation.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| digital filter | Whether to enable the digital filter | false | - | [true, false] |
| single tap filter | Whether to use a single-tap filter | false | - | [true, false] |
| number of taps estimation | Tap-count estimation method | fit tolerance | - | [disabled, fit tolerance, group delay] |
| filter fit tolerance | Filter fit tolerance | 0.001 | - | (0, 1) |
| window function | Window function | rectangular | - | [rectangular, hamming, hanning] |
| number of fir taps | Number of FIR taps | 256 | - | [1, +∞) |
| maximum number of fir taps | Upper limit on the number of FIR taps | 4096 | - | [1, +∞) |
| initialize filter taps | Whether to initialize filter taps | false | - | [true, false] |
| fractional delay | Whether to enable fractional delay | true | - | [true, false] |
| delay compensation | Delay compensation amount | 0 | - | [0, +∞) |
Diagnostic #
Used to compare the deviation between the ideal frequency response and the digital filter response actually used.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| run diagnostic | Whether to run diagnostics | false | - | [true, false] |
| diagnostic size | Number of diagnostic data points or buffer size | 1024 | - | [2, +∞) |
Results #
When run diagnostic is enabled, time-domain sample-mode simulation produces the following results for verifying the response:
![]()
diagnostic/response
| Name | Description |
|---|---|
| transmission | Complex transmittance versus frequency for the ideal and fitted responses. |
| gain | Gain (dB) versus frequency for the ideal and fitted responses. |
| error | Relative mean-square error between the ideal and fitted magnitudes. |
The response number corresponds to a pair of input port, output port, and mode.