Waveguide Arc Bend

Waveguide Arc Bend

WGD

Waveguide Arc Bend (WGD) is a waveguide segment with constant bend radius, used to change optical path direction or form the curved portion of ring structures. Smaller bend radii make radiation loss and mode mismatch more significant. Arc length is determined jointly by radius and central angle, and can be used to evaluate bend loss and optimize layout compactness.

Ports

Two optical signal ports, one at each end of the bend segment. Bidirectional by default; can also be switched to unidirectional.

Name Type Data
port 1 Optical Signal Bidirectional
port 2 Optical Signal Bidirectional

The table reflects the default bidirectional configuration; after changing configuration, port directions may change.

Properties

General

Identifies and manages the element itself, including name, annotation, enable state, and display style. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name WGD_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether the element is enabled true - [true, false]
type Unique type identifier of the element Waveguide Arc Bend - -
description Brief description of the element The model of a constant bending radius waveguide - -
prefix Prefix for the element name WGD - -
local path Local path or working folder of the element - - -

Standard

Defines the geometry and operating frequency of the bend segment, which determine the turning angle and bend loss.

Name Description Default value Default unit Range
configuration Port configuration bidirectional - [bidirectional, unidirectional]
frequency Frequency 193.1 THz (0, +∞)
angle Angle 0 rad (-∞, +∞)
radius Radius 0 m (0, +∞)

Waveguide / Mode 1

Sets the transmission parameters of mode 1 (typically TE) in the bend segment, including excess loss, phase accumulation, and dispersion.

Name Description Default value Default unit Range
orthogonal identifier 1 Orthogonal identifier of mode 1 1 - [1, +∞)
label 1 Label of mode 1 TE - -
loss 1 Loss of mode 1 0 dB [0, +∞)
effective index 1 Effective index of mode 1 1 - (-∞, +∞)
group index 1 Group index of mode 1 1 - [0, +∞)
dispersion 1 Dispersion of mode 1 0 s/m/m (-∞, +∞)
dispersion slope 1 Dispersion slope of mode 1 0 s/m^2/m (-∞, +∞)

Waveguide / Mode 1 / Thermal

Sets the temperature coefficients of mode 1, describing how temperature changes affect refractive index and loss.

Name Description Default value Default unit Range
effective index temperature sensitivity 1 Temperature sensitivity of the effective index of mode 1 0 /K (-∞, +∞)
excess loss temperature sensitivity 1 Temperature sensitivity of the excess loss of mode 1 0 /K [0, +∞)

Waveguide / Mode 2

Sets the transmission parameters of mode 2 (typically TM) in the bend segment, used to describe polarization-dependent bend loss.

Name Description Default value Default unit Range
orthogonal identifier 2 Orthogonal identifier of mode 2 2 - [1, +∞)
label 2 Label of mode 2 TM - -
loss 2 Loss of mode 2 0 dB [0, +∞)
effective index 2 Effective index of mode 2 1 - (-∞, +∞)
group index 2 Group index of mode 2 1 - [0, +∞)
dispersion 2 Dispersion of mode 2 0 s/m/m (-∞, +∞)
dispersion slope 2 Dispersion slope of mode 2 0 s/m^2/m (-∞, +∞)

Waveguide / Mode 2 / Thermal

Sets the temperature coefficients of mode 2; the role is the same as for mode 1.

Name Description Default value Default unit Range
effective index temperature sensitivity 2 Temperature sensitivity of the effective index of mode 2 0 /K (-∞, +∞)
excess loss temperature sensitivity 2 Temperature sensitivity of the excess loss of mode 2 0 /K [0, +∞)

Thermal

Controls whether thermal effects are enabled, and specifies the operating temperature and the fraction of waveguide length affected by heating.

Name Description Default value Default unit Range
thermal effects Whether to enable thermal effects false - [true, false]
temperature Temperature %temperature% K (-∞, +∞)
nominal temperature Nominal temperature 300 K (-∞, +∞)
thermal fill factor Fraction of waveguide length affected by thermal effects 1 - [0, 1]

Numerical / Digital Filter

Fits the device frequency-domain response to a digital filter required for time-domain simulation.

Name Description Default value Default unit Range
digital filter Whether to enable the digital filter false - [true, false]
single tap filter Whether to use a single-tap filter false - [true, false]
number of taps estimation Tap-count estimation method fit tolerance - [disabled, fit tolerance, group delay]
filter fit tolerance Filter fit tolerance 0.001 - (0, 1)
window function Window function rectangular - [rectangular, hamming, hanning]
number of fir taps Number of FIR taps 256 - [1, +∞)
maximum number of fir taps Upper limit on the number of FIR taps 4096 - [1, +∞)
initialize filter taps Whether to initialize filter taps false - [true, false]
fractional delay Whether to enable fractional delay true - [true, false]
delay compensation Delay compensation amount 0 - [0, +∞)

Diagnostic

Used to compare the deviation between the ideal frequency response and the digital filter response actually used.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)

Results

When run diagnostic is enabled, time-domain sample-mode simulation produces the following results for verifying the response:

Results

diagnostic/response

Name Description
transmission Complex transmittance versus frequency for the ideal and fitted responses.
gain Gain (dB) versus frequency for the ideal and fitted responses.
error Relative mean-square error between the ideal and fitted magnitudes.

The response number corresponds to a pair of input port, output port, and mode.