Straight Waveguide

Straight Waveguide

WGD

Straight Waveguide (WGD) is the most basic optical waveguide model, describing the phase, loss, group delay, and dispersion accumulated as light propagates along a straight waveguide. Its length determines how much phase and loss accumulate, while the mode parameters determine phase velocity, delay, and dispersion. It is a fundamental building block for structures such as ring resonators, Mach–Zehnder interferometers, and delay lines.

Ports

Two optical signal ports. Bidirectional by default; can also be switched to unidirectional.

Name Type Data
port 1 Optical Signal Bidirectional
port 2 Optical Signal Bidirectional

The table reflects the default bidirectional configuration; after changing configuration, port directions may change.

Properties

General

Identifies and manages the element itself, including name, annotation, enable state, and display style. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name WGD_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether the element is enabled true - [true, false]
type Unique type identifier of the element Straight Waveguide - -
description Brief description of the element Optical straight waveguide - -
prefix Prefix for the element name WGD - -
local path Local path or working folder of the element - - -

Standard

Defines waveguide length and operating frequency—the primary settings that determine phase, delay, and loss accumulation.

Name Description Default value Default unit Range
configuration Port configuration bidirectional - [bidirectional, unidirectional]
frequency Frequency 193.1 THz (0, +∞)
length Length 1e-5 m [0, +∞)

Waveguide / Mode 1

Sets the transmission parameters of mode 1 (typically TE), which determine phase accumulation, delay, loss, and dispersion for that mode.

Name Description Default value Default unit Range
orthogonal identifier 1 Orthogonal identifier of mode 1 1 - [1, +∞)
label 1 Label of mode 1 TE - -
loss 1 Loss of mode 1 0 dB/m [0, +∞)
effective index 1 Effective index of mode 1 1 - (-∞, +∞)
group index 1 Group index of mode 1 1 - [0, +∞)
dispersion 1 Dispersion of mode 1 0 s/m/m (-∞, +∞)
dispersion slope 1 Dispersion slope of mode 1 0 s/m^2/m (-∞, +∞)

Waveguide / Mode 1 / Thermal

Sets the temperature coefficients of mode 1, describing how temperature changes affect refractive index and loss.

Name Description Default value Default unit Range
effective index temperature sensitivity 1 Temperature sensitivity of the effective index of mode 1 0 /K (-∞, +∞)
excess loss temperature sensitivity 1 Temperature sensitivity of the excess loss of mode 1 0 /K [0, +∞)

Waveguide / Mode 2

Sets the transmission parameters of mode 2 (typically TM), used to describe polarization-dependent transmission characteristics.

Name Description Default value Default unit Range
orthogonal identifier 2 Orthogonal identifier of mode 2 2 - [1, +∞)
label 2 Label of mode 2 TM - -
loss 2 Loss of mode 2 0 dB/m [0, +∞)
effective index 2 Effective index of mode 2 1 - (-∞, +∞)
group index 2 Group index of mode 2 1 - [0, +∞)
dispersion 2 Dispersion of mode 2 0 s/m/m (-∞, +∞)
dispersion slope 2 Dispersion slope of mode 2 0 s/m^2/m (-∞, +∞)

Waveguide / Mode 2 / Thermal

Sets the temperature coefficients of mode 2; the role is the same as for mode 1.

Name Description Default value Default unit Range
effective index temperature sensitivity 2 Temperature sensitivity of the effective index of mode 2 0 /K (-∞, +∞)
excess loss temperature sensitivity 2 Temperature sensitivity of the excess loss of mode 2 0 /K [0, +∞)

Thermal

Controls whether thermal effects are enabled, and specifies the operating temperature and the fraction of waveguide length affected by heating.

Name Description Default value Default unit Range
thermal effects Whether to enable thermal effects false - [true, false]
temperature Temperature %temperature% K (-∞, +∞)
nominal temperature Nominal temperature 300 K (-∞, +∞)
thermal fill factor Fraction of waveguide length affected by thermal effects 1 - [0, 1]

Numerical / Digital Filter

Fits the device frequency-domain response to a digital filter required for time-domain simulation.

Name Description Default value Default unit Range
digital filter Whether to enable the digital filter false - [true, false]
single tap filter Whether to use a single-tap filter false - [true, false]
number of taps estimation Tap-count estimation method fit tolerance - [disabled, fit tolerance, group delay]
filter fit tolerance Filter fit tolerance 0.001 - (0, 1)
window function Window function rectangular - [rectangular, hamming, hanning]
number of fir taps Number of FIR taps 256 - [1, +∞)
maximum number of fir taps Upper limit on the number of FIR taps 4096 - [1, +∞)
initialize filter taps Whether to initialize filter taps false - [true, false]
fractional delay Whether to enable fractional delay true - [true, false]
delay compensation Delay compensation amount 0 - [0, +∞)

Diagnostic

Used to compare the deviation between the ideal frequency response and the digital filter response actually used.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)

Results

When run diagnostic is enabled, the following nodes appear in the results for verifying the waveguide response fit:

Results

diagnostic/response

Name Description
transmission Complex transmittance versus frequency for the ideal and fitted responses.
gain Gain (dB) versus frequency for the ideal and fitted responses.
error Relative mean-square error between the ideal and fitted magnitudes.