PIN Photodetector

PIN Photodetector

PIN

PIN Photodetector (PIN) converts input optical power into an electrical signal as the first stage of an optical receiver link. The conversion ratio is set by responsivity; dark current still contributes a DC component under zero optical input. Shot noise, thermal noise, and power saturation can be enabled separately to better approximate real-device receiver behavior. The output electrical signal can be sent directly to filters, eye-diagram, or data-recovery elements.

Ports

input receives the optical signal; output delivers the detected electrical signal.

Name Type Data
input Optical Signal Input
output Electrical Signal Output

Properties

General

Used to identify and manage the element itself, including name, annotation, enabled state, and display. This group of properties only affects schematic presentation and does not change device behavior.

Name Description Default value Default unit Range
name Element name PIN_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether the element is enabled true - [true, false]
type Unique type identifier of the element PIN Photodetector - -
description Brief description of the element PIN photodetector - -
prefix Prefix for the element name PIN - -
local path Local path or working folder of the element - - -

Standard

Sets the detection characteristics of the device, which determine photoelectric conversion efficiency and noise level.

Name Description Default value Default unit Range
frequency at max power Whether to use the frequency corresponding to maximum power true - [true, false]
frequency Frequency 193.1 THz (0, +∞)
input parameter Parameter input method constant - [constant, table]
responsivity Responsivity 1 A/W (0, +∞)
load from file Whether to load data from a file false - [true, false]
measurement filename Measurement data file name - - -
measurement Measurement data table 1×2; columns: frequency (Hz), responsivity (A/W); first row [1.931e14, 1] - -
dark current Dark current 0 A [0, +∞)
thermal noise Thermal noise 1e-22 A/Hz^.5 [0, +∞)
saturation power Saturation power 20 mW (0, +∞)

Numerical

Controls whether power saturation and each noise type are included, and the repeatability of the noise.

Name Description Default value Default unit Range
enable power saturation Whether to enable power saturation false - [true, false]
enable thermal noise Whether to enable thermal noise true - [true, false]
enable shot noise Whether to enable shot noise true - [true, false]
convert noise bins Whether to convert noise bins true - [true, false]
automatic seed Whether to generate a random seed automatically true - [true, false]
seed Random seed 1 - [0, +∞)

Numerical / Digital Filter

Fits the device frequency response to a digital filter required for time-domain simulation.

Name Description Default value Default unit Range
single tap filter Whether to use a single-tap filter false - [true, false]
number of taps estimation Method for estimating the number of taps fit tolerance - [disabled, fit tolerance, group delay]
filter fit tolerance Filter fit tolerance 0.001 - (0, 1)
window function Window function rectangular - [rectangular, hamming, hanning]
number of fir taps Number of FIR taps 256 - [1, +∞), power of 2
maximum number of fir taps Upper limit on the number of FIR taps 4096 - [1, +∞), power of 2
filter delay Filter delay 0 s [0, +∞)
initialize filter taps Whether to initialize filter taps false - [true, false]

Diagnostic

Used to check the deviation between the ideal response and the digital-filter fit to confirm frequency-domain accuracy in time-domain simulation. Keep disabled for routine simulation.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)

Results

After run diagnostic is enabled, the following nodes appear in the results:

Results

diagnostic/response

Name Description
transmission Variation of the complex transmittance of the ideal response and the fitted response with frequency.
gain Variation of the gain (dB) of the ideal response and the fitted response with frequency.
error Relative mean square error between the ideal amplitude and the fitted amplitude.