Optical Y Switch

Optical Y Switch

Y

Optical Y Switch (Y) is a 1×2 optical switch that can route one optical path to either of two branches, or operate in reverse as a 2×1 combiner. It is suited to simple optical routing, monitor-branch selection, and as a basic building block of tree switching networks.

Ports

Three bidirectional optical ports: one common port and two branch ports. The table expands the default configuration.

Name Type Data
port 1 Optical Signal Bidirectional
port 2 Optical Signal Bidirectional
port 3 Optical Signal Bidirectional

After changing configuration, port directions may change.

Properties

General

Used to identify and manage the element itself, including name, annotation, enable state, and display options. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name Y_1 - -
annotate Whether to display the annotation true - [true, false]
enabled Whether to enable this element true - [true, false]
type Unique type identifier of the element Optical Y Switch - -
description Brief description of the element Optical 1x2 switch - -
prefix Prefix for the element name Y - -
local path Local path or working folder of the element - - -

Standard

Sets the switch operating mode, active branch, and performance metrics.

Name Description Default value Default unit Range
configuration Port configuration bidirectional - [bidirectional, switch, select]
control Control state or control quantity 0 - -
insertion loss Insertion loss 0 dB [0, +∞)
isolation Isolation 100 dB (-∞, +∞)
return loss Return loss 100 dB (-∞, +∞)

Waveguide

Lists the optical modes supported by this element for interfacing with connected waveguides and devices.

Name Description Default value Default unit Range
modes Optical mode labels, comma-separated in English, e.g. TE,TM TE,TM - -

Diagnostic

Used to check the deviation between the ideal response and the digital filter fit, to confirm frequency-domain accuracy of time-domain simulation. Keep disabled for routine simulations.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)

Results

When run diagnostic is enabled, time-domain sampled simulation produces the following results for verifying the response:

Results

diagnostic/response

Name Description
transmission Complex transmittance versus frequency for the ideal and fitted responses.
gain Gain (dB) versus frequency for the ideal and fitted responses.
error Relative mean-square error between ideal and fitted amplitudes.

The response number corresponds to a pair of input port, output port, and mode.