Optical Switch

Optical Switch

X

Optical Switch (X) is a 2×2 optical switch that changes connectivity between two pairs of optical ports, supporting bar (1→3, 2→4) or cross (1→4, 2→3) connections. The connectivity is controlled by the control property. This element is used for optical path switching, protection switching, and reconfigurable optical networks, and can be cascaded into multi-stage switch matrices.

Ports

Four bidirectional optical ports connected as a 2×2 switch. The table shows the default configuration.

Name Type Data
port 1 Optical Signal Bidirectional
port 2 Optical Signal Bidirectional
port 3 Optical Signal Bidirectional
port 4 Optical Signal Bidirectional

After changing configuration, the port directions may change.

Properties

General

Used to identify and manage the element itself, including name, annotation, enabled state, and display. This group of properties only affects schematic presentation and does not change device behavior.

Name Description Default value Default unit Range
name Element name X_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether the element is enabled true - [true, false]
type Unique type identifier of the element Optical Switch - -
description Brief description of the element Optical 2x2 switch - -
prefix Prefix for the element name X - -
local path Local path or working folder of the element - - -

Standard

Sets the switch on/off state and performance metrics that determine the current routing and signal attenuation.

Name Description Default value Default unit Range
configuration Port configuration bidirectional - [bidirectional, unidirectional]
control Control state or control value 0 - -
insertion loss Insertion loss 0 dB [0, +∞)
isolation Isolation 100 dB (-∞, +∞)
return loss Return loss 100 dB (-∞, +∞)

Waveguide

Lists the optical modes supported by this element for interfacing with connected waveguides and devices.

Name Description Default value Default unit Range
modes Optical mode labels, separated by English commas, e.g. TE,TM TE,TM - -

Diagnostic

Used to check the deviation between the ideal response and the digital-filter fit to confirm frequency-domain accuracy in time-domain simulation. Keep disabled for routine simulation.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)

Results

When run diagnostic is enabled, time-domain sampled simulation produces the following results for response verification:

Results

diagnostic/response

Name Description
transmission Complex transmittance of the ideal and fitted responses versus frequency.
gain Gain (dB) of the ideal and fitted responses versus frequency.
error Relative mean-square error between the ideal and fitted amplitudes.

The response number corresponds to a pair of input port, output port, and mode.