Optical Attenuator

Optical Attenuator

ATT

Optical Attenuator (ATT) reduces optical signal power by a set amount, changing only the power level without adding dispersion or phase models. It is suited to link power budgeting, avoiding photodetector or amplifier saturation, and inter-stage power adjustment.

Ports

Two optical signal ports. Bidirectional by default; can also be switched to unidirectional.

Name Type Data
port 1 Optical Signal Bidirectional
port 2 Optical Signal Bidirectional

The table expands the default bidirectional configuration; after changing configuration, port directions may change.

Properties

General

Used to identify and manage the element itself, including name, annotation, enable state, and display options. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name ATT_1 - -
annotate Whether to display the annotation true - [true, false]
enabled Whether to enable this element true - [true, false]
type Unique type identifier of the element Optical Attenuator - -
description Brief description of the element It reduces the power level of an optical signal - -
prefix Prefix for the element name ATT - -
local path Local path or working folder of the element - - -

Standard

Sets the attenuation amount and reflection characteristics, which determine how much optical power is reduced.

Name Description Default value Default unit Range
configuration Port configuration bidirectional - [bidirectional, unidirectional]
attenuation Attenuation 0 dB (-∞, +∞)
enable return loss Whether to enable return loss false - [true, false]
return loss Return loss 100 dB [0, +∞)

Waveguide

Lists the optical modes supported by this element for interfacing with connected waveguides and devices.

Name Description Default value Default unit Range
modes Optical mode labels, comma-separated in English, e.g. TE,TM TE,TM - -

Diagnostic

Used to check the deviation between the ideal response and the digital filter fit, to confirm frequency-domain accuracy of time-domain simulation. Keep disabled for routine simulations.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)

Results

When run diagnostic is enabled, time-domain sampled simulation produces the following results for verifying the response:

Results

diagnostic/response

Name Description
transmission Complex transmittance versus frequency for the ideal and fitted responses.
gain Gain (dB) versus frequency for the ideal and fitted responses.
error Relative mean-square error between ideal and fitted amplitudes.

The response number corresponds to a pair of input port, output port, and mode.