NRZ Pulse Generator
NRZ Pulse Generator #
![]()
NRZ Pulse Generator (NRZ) converts an input bit sequence into a non-return-to-zero (NRZ) electrical pulse waveform: each bit maps to a level, and the signal does not return to zero between bits. It is typically used with a PRBS generator to convert a bit stream into an electrical signal with defined amplitude, bias, and edge transitions for modulator drive or receiver-link excitation.
Ports #
input receives a digital bit sequence; output delivers the NRZ electrical pulse waveform.
| Name | Type | Data |
|---|---|---|
| input | Digital Signal | Input |
| output | Electrical Signal | Output |
Properties #
General #
Used to identify and manage the element itself, including name, annotation, enabled state, and display. This group of properties only affects schematic presentation and does not change device behavior.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| name | Element name | NRZ_1 | - | - |
| annotate | Whether to show annotation | true | - | [true, false] |
| enabled | Whether the element is enabled | true | - | [true, false] |
| type | Unique type identifier of the element | NRZ Pulse Generator | - | - |
| description | Brief description of the element | The NRZ Generator pulse generator creates a sequence of non-return to zero pulses coded by an input digital signal | - | - |
| prefix | Prefix for the element name | NRZ | - | - |
| local path | Local path or working folder of the element | - | - | - |
Standard #
Sets the output waveform levels and edges, which determine pulse amplitude, bias, and transition-time fractions.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| amplitude | Amplitude | 1 | a.u. | (-∞, +∞) |
| bias | Bias | 0 | a.u. | (-∞, +∞) |
| rise period | Rise-time fraction | 0.05 | - | [0, 1] |
| fall period | Fall-time fraction | 0.05 | - | [0, 1] |
Enhanced #
Sets pre-emphasis and overshoot/undershoot to compensate high-frequency loss in the link.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| pre emphasis | Pre-emphasis | false | - | [true, false] |
| overshoot factor | Overshoot factor | 0 | - | [0, +∞) |
| overshoot period | Overshoot period | 0 | - | (0, 1] |
| undershoot factor | Undershoot factor | 0 | - | [0, +∞) |
| undershoot period | Undershoot period | 0 | - | (0, 1] |
Simulation #
Sets how the signal is generated and output. By default these inherit the top-level simulation settings and usually need no change.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| output signal mode | Output signal mode | %output signal mode% |
- | [sample, block] |
| sample rate | Sample rate | %sample rate% |
Hz | [0, +∞) |
Results #