Mach Zehnder Interferometer
Mach Zehnder Interferometer #
![]()
Mach Zehnder Interferometer (MZI) splits the input light into two paths, propagates them through arms of different lengths, and recombines them. The optical path difference between the arms introduces a phase difference; on recombination, in-phase components interfere constructively and out-of-phase components destructively. Changing arm length, refractive index, or temperature therefore controls the output optical power.
Ports #
Four bidirectional optical signal ports forming a 2×2 interferometer. The table shows the default configuration.
| Name | Type | Data |
|---|---|---|
| port 1 | Optical Signal | Bidirectional |
| port 2 | Optical Signal | Bidirectional |
| port 3 | Optical Signal | Bidirectional |
| port 4 | Optical Signal | Bidirectional |
After changing configuration, the port directions may change.
Properties #
General #
Used to identify and manage the element itself, including name, annotation, enabled state, and display. This group of properties only affects schematic presentation and does not change device behavior.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| name | Element name | MZI_1 | - | - |
| annotate | Whether to show annotation | true | - | [true, false] |
| enabled | Whether the element is enabled | true | - | [true, false] |
| type | Unique type identifier of the element | Mach Zehnder Interferometer | - | - |
| description | Brief description of the element | Mach Zehnder interferometer | - | - |
| prefix | Prefix for the element name | MZI | - | - |
| local path | Local path or working folder of the element | - | - | - |
Standard #
Defines the two arm lengths and operating frequency, which determine the arm phase difference and the interference result.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| configuration | Port configuration | bidirectional | - | [bidirectional, unidirectional] |
| frequency | Frequency | 193.1 | THz | (0, +∞) |
| length 1 | Length 1 | 1e-5 | m | [0, +∞) |
| length 2 | Length 2 | 1e-5 | m | [0, +∞) |
Waveguide / Mode 1 #
Sets the transmission parameters of mode 1 (typically TE) in both arms, which determine phase accumulation, delay, and loss.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| orthogonal identifier 1 | Orthogonal identifier of mode 1 | 1 | - | [1, +∞) |
| label 1 | Label of mode 1 | TE | - | - |
| loss 1 | Loss of mode 1 | 0 | dB/m | [0, +∞) |
| effective index 1 | Effective refractive index of mode 1 | 1 | - | (-∞, +∞) |
| group index 1 | Group refractive index of mode 1 | 1 | - | [0, +∞) |
| dispersion 1 | Dispersion of mode 1 | 0 | s/m/m | (-∞, +∞) |
| dispersion slope 1 | Dispersion slope of mode 1 | 0 | s/m^2/m | (-∞, +∞) |
Waveguide / Mode 1 / Coupler #
Sets the power-splitting ratios at the splitter and combiner for mode 1, which determine interference contrast and output distribution.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| coupling coefficient 1 1 | Coupling coefficient for mode 1, coupler region 1 | 0.5 | - | [0, 1] |
| coupling coefficient 1 2 | Coupling coefficient for mode 1, coupler region 2 | 0.5 | - | [0, 1] |
Waveguide / Mode 1 / Thermal #
Sets the temperature coefficients of mode 1, which determine the efficiency and sensitivity of thermo-optic tuning.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| effective index temperature sensitivity 1 | Temperature sensitivity of the effective refractive index of mode 1 | 0 | /K | (-∞, +∞) |
| excess loss temperature sensitivity 1 | Temperature sensitivity of the excess loss of mode 1 | 0 | /K | [0, +∞) |
Waveguide / Mode 2 #
Sets the transmission parameters of mode 2 (typically TM) in both arms, which determine phase accumulation, delay, and loss.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| orthogonal identifier 2 | Orthogonal identifier of mode 2 | 2 | - | [1, +∞) |
| label 2 | Label of mode 2 | TM | - | - |
| loss 2 | Loss of mode 2 | 0 | dB/m | [0, +∞) |
| effective index 2 | Effective refractive index of mode 2 | 1 | - | (-∞, +∞) |
| group index 2 | Group refractive index of mode 2 | 1 | - | [0, +∞) |
| dispersion 2 | Dispersion of mode 2 | 0 | s/m/m | (-∞, +∞) |
| dispersion slope 2 | Dispersion slope of mode 2 | 0 | s/m^2/m | (-∞, +∞) |
Waveguide / Mode 2 / Coupler #
Sets the power-splitting ratios at the splitter and combiner for mode 2; the role is the same as for mode 1.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| coupling coefficient 2 1 | Coupling coefficient for mode 2, coupler region 1 | 0.5 | - | [0, 1] |
| coupling coefficient 2 2 | Coupling coefficient for mode 2, coupler region 2 | 0.5 | - | [0, 1] |
Waveguide / Mode 2 / Thermal #
Sets the temperature coefficients of mode 2; the role is the same as for mode 1.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| effective index temperature sensitivity 2 | Temperature sensitivity of the effective refractive index of mode 2 | 0 | /K | (-∞, +∞) |
| excess loss temperature sensitivity 2 | Temperature sensitivity of the excess loss of mode 2 | 0 | /K | [0, +∞) |
Thermal #
Controls whether thermal effects of the MZI are enabled, and specifies the operating temperature and the fraction of waveguide length affected by heating.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| thermal effects | Whether to enable thermal effects | false | - | [true, false] |
| temperature | Temperature | %temperature% |
K | (-∞, +∞) |
| nominal temperature | Nominal temperature | 300 | K | (-∞, +∞) |
| thermal fill factor | Fraction of waveguide length affected by thermal effects | 1 | - | [0, 1] |
Numerical / Digital Filter #
Fits the device frequency response to a digital filter required for time-domain simulation.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| single tap filter | Whether to use a single-tap filter | false | - | [true, false] |
| number of taps estimation | Method for estimating the number of taps | fit tolerance | - | [disabled, fit tolerance, group delay] |
| filter fit tolerance | Filter fit tolerance | 0.001 | - | (0, 1) |
| window function | Window function | rectangular | - | [rectangular, hamming, hanning] |
| number of fir taps | Number of FIR taps | 256 | - | [1, +∞), power of 2 |
| maximum number of fir taps | Upper limit on the number of FIR taps | 4096 | - | [1, +∞) |
| filter delay | Filter delay | 0 | s | [0, +∞) |
| initialize filter taps | Whether to initialize filter taps | false | - | [true, false] |
Diagnostic #
Used to check the deviation between the ideal response and the digital-filter fit to confirm frequency-domain accuracy in time-domain simulation. Keep disabled for routine simulation.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| run diagnostic | Whether to run diagnostics | false | - | [true, false] |
| diagnostic size | Number of diagnostic data points or buffer size | 1024 | - | [2, +∞) |
Results #
When run diagnostic is enabled, time-domain sampled simulation produces the following results for response verification:
![]()
diagnostic/response
| Name | Description |
|---|---|
| transmission | Complex transmittance of the ideal and fitted responses versus frequency. |
| gain | Gain (dB) of the ideal and fitted responses versus frequency. |
| error | Relative mean-square error between the ideal and fitted amplitudes. |
The response number corresponds to a pair of input port, output port, and mode.