Mach Zehnder Interferometer

Mach Zehnder Interferometer

MZI

Mach Zehnder Interferometer (MZI) splits the input light into two paths, propagates them through arms of different lengths, and recombines them. The optical path difference between the arms introduces a phase difference; on recombination, in-phase components interfere constructively and out-of-phase components destructively. Changing arm length, refractive index, or temperature therefore controls the output optical power.

Ports

Four bidirectional optical signal ports forming a 2×2 interferometer. The table shows the default configuration.

Name Type Data
port 1 Optical Signal Bidirectional
port 2 Optical Signal Bidirectional
port 3 Optical Signal Bidirectional
port 4 Optical Signal Bidirectional

After changing configuration, the port directions may change.

Properties

General

Used to identify and manage the element itself, including name, annotation, enabled state, and display. This group of properties only affects schematic presentation and does not change device behavior.

Name Description Default value Default unit Range
name Element name MZI_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether the element is enabled true - [true, false]
type Unique type identifier of the element Mach Zehnder Interferometer - -
description Brief description of the element Mach Zehnder interferometer - -
prefix Prefix for the element name MZI - -
local path Local path or working folder of the element - - -

Standard

Defines the two arm lengths and operating frequency, which determine the arm phase difference and the interference result.

Name Description Default value Default unit Range
configuration Port configuration bidirectional - [bidirectional, unidirectional]
frequency Frequency 193.1 THz (0, +∞)
length 1 Length 1 1e-5 m [0, +∞)
length 2 Length 2 1e-5 m [0, +∞)

Waveguide / Mode 1

Sets the transmission parameters of mode 1 (typically TE) in both arms, which determine phase accumulation, delay, and loss.

Name Description Default value Default unit Range
orthogonal identifier 1 Orthogonal identifier of mode 1 1 - [1, +∞)
label 1 Label of mode 1 TE - -
loss 1 Loss of mode 1 0 dB/m [0, +∞)
effective index 1 Effective refractive index of mode 1 1 - (-∞, +∞)
group index 1 Group refractive index of mode 1 1 - [0, +∞)
dispersion 1 Dispersion of mode 1 0 s/m/m (-∞, +∞)
dispersion slope 1 Dispersion slope of mode 1 0 s/m^2/m (-∞, +∞)

Waveguide / Mode 1 / Coupler

Sets the power-splitting ratios at the splitter and combiner for mode 1, which determine interference contrast and output distribution.

Name Description Default value Default unit Range
coupling coefficient 1 1 Coupling coefficient for mode 1, coupler region 1 0.5 - [0, 1]
coupling coefficient 1 2 Coupling coefficient for mode 1, coupler region 2 0.5 - [0, 1]

Waveguide / Mode 1 / Thermal

Sets the temperature coefficients of mode 1, which determine the efficiency and sensitivity of thermo-optic tuning.

Name Description Default value Default unit Range
effective index temperature sensitivity 1 Temperature sensitivity of the effective refractive index of mode 1 0 /K (-∞, +∞)
excess loss temperature sensitivity 1 Temperature sensitivity of the excess loss of mode 1 0 /K [0, +∞)

Waveguide / Mode 2

Sets the transmission parameters of mode 2 (typically TM) in both arms, which determine phase accumulation, delay, and loss.

Name Description Default value Default unit Range
orthogonal identifier 2 Orthogonal identifier of mode 2 2 - [1, +∞)
label 2 Label of mode 2 TM - -
loss 2 Loss of mode 2 0 dB/m [0, +∞)
effective index 2 Effective refractive index of mode 2 1 - (-∞, +∞)
group index 2 Group refractive index of mode 2 1 - [0, +∞)
dispersion 2 Dispersion of mode 2 0 s/m/m (-∞, +∞)
dispersion slope 2 Dispersion slope of mode 2 0 s/m^2/m (-∞, +∞)

Waveguide / Mode 2 / Coupler

Sets the power-splitting ratios at the splitter and combiner for mode 2; the role is the same as for mode 1.

Name Description Default value Default unit Range
coupling coefficient 2 1 Coupling coefficient for mode 2, coupler region 1 0.5 - [0, 1]
coupling coefficient 2 2 Coupling coefficient for mode 2, coupler region 2 0.5 - [0, 1]

Waveguide / Mode 2 / Thermal

Sets the temperature coefficients of mode 2; the role is the same as for mode 1.

Name Description Default value Default unit Range
effective index temperature sensitivity 2 Temperature sensitivity of the effective refractive index of mode 2 0 /K (-∞, +∞)
excess loss temperature sensitivity 2 Temperature sensitivity of the excess loss of mode 2 0 /K [0, +∞)

Thermal

Controls whether thermal effects of the MZI are enabled, and specifies the operating temperature and the fraction of waveguide length affected by heating.

Name Description Default value Default unit Range
thermal effects Whether to enable thermal effects false - [true, false]
temperature Temperature %temperature% K (-∞, +∞)
nominal temperature Nominal temperature 300 K (-∞, +∞)
thermal fill factor Fraction of waveguide length affected by thermal effects 1 - [0, 1]

Numerical / Digital Filter

Fits the device frequency response to a digital filter required for time-domain simulation.

Name Description Default value Default unit Range
single tap filter Whether to use a single-tap filter false - [true, false]
number of taps estimation Method for estimating the number of taps fit tolerance - [disabled, fit tolerance, group delay]
filter fit tolerance Filter fit tolerance 0.001 - (0, 1)
window function Window function rectangular - [rectangular, hamming, hanning]
number of fir taps Number of FIR taps 256 - [1, +∞), power of 2
maximum number of fir taps Upper limit on the number of FIR taps 4096 - [1, +∞)
filter delay Filter delay 0 s [0, +∞)
initialize filter taps Whether to initialize filter taps false - [true, false]

Diagnostic

Used to check the deviation between the ideal response and the digital-filter fit to confirm frequency-domain accuracy in time-domain simulation. Keep disabled for routine simulation.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)

Results

When run diagnostic is enabled, time-domain sampled simulation produces the following results for response verification:

Results

diagnostic/response

Name Description
transmission Complex transmittance of the ideal and fitted responses versus frequency.
gain Gain (dB) of the ideal and fitted responses versus frequency.
error Relative mean-square error between the ideal and fitted amplitudes.

The response number corresponds to a pair of input port, output port, and mode.