LP Bessel Filter

LP Bessel Filter

LPF

LP Bessel Filter (LPF) is a low-pass filter. The Bessel response has near-linear phase in the passband, so it can limit bandwidth while preserving pulse shape well, with small edge overshoot and ringing. It is often placed after a photodetector or amplifier to suppress out-of-band noise, shape pulses, and serve as front-end filtering for eye diagrams and data recovery.

Ports

input receives an electrical signal; output delivers the filtered electrical signal.

Name Type Data
input Electrical Signal Input
output Electrical Signal Output

Properties

General

Used to identify and manage the element itself, including name, annotation, enable state, and display options. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name LPF_1 - -
annotate Whether to display the annotation true - [true, false]
enabled Whether to enable this element true - [true, false]
type Unique type identifier of the element LP Bessel Filter - -
description Brief description of the element Electrical low pass (LP) Bessel filter - -
prefix Prefix for the element name LPF - -
local path Local path or working folder of the element - - -

Standard

Sets filter characteristics that determine bandwidth limiting and pulse-shaping behavior.

Name Description Default value Default unit Range
cutoff frequency Cutoff frequency 0.75 * %bitrate% GHz (0, +∞)
order Order of the Bessel filter 4 - [1, 10]
insertion loss Insertion loss 0 dB [0, +∞)

Numerical / Digital Filter

Sets the initialization behavior of the digital filter in time-domain simulation; typically leave at defaults.

Name Description Default value Default unit Range
initialize filter taps Whether to initialize filter taps false - [true, false]

Diagnostic

Used to check the deviation between the ideal filter response and the digital filter fit.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)

Results

When run diagnostic is enabled, time-domain sampled simulation produces the following results for verifying the filter response:

Results

diagnostic/response

Name Description
transmission Complex transmittance versus frequency for the ideal and fitted responses.
gain Gain (dB) versus frequency for the ideal and fitted responses.
error Relative mean-square error between ideal and fitted amplitudes.

The response number corresponds to a pair of input port, output port, and mode.