Double Bus Ring Resonator

Double Bus Ring Resonator

RING

The Double Bus Ring Resonator (RING) is a dual-bus (add-drop) ring resonator formed by a through bus and a drop bus, and is a basic building block of an optical add-drop multiplexer (OADM). After input light enters the through bus, non-resonant wavelengths continue along the through port; resonant wavelengths couple into the ring, circulate once, and are coupled at the second coupler onto the drop bus for output, yielding wavelength selectivity. The resonant wavelength is set by ring circumference and effective index. Coupling strengths of the two couplers are independently adjustable and affect intra-ring energy build-up and drop efficiency. Used in reverse, the drop bus can also serve as an add port to inject a same-wavelength signal.

Ports

Four bidirectional optical signal ports: two ports on each of the two buses. The table shows the default configuration.

Name Type Data
port 1 Optical Signal Bidirectional
port 2 Optical Signal Bidirectional
port 3 Optical Signal Bidirectional
port 4 Optical Signal Bidirectional

Changing configuration may alter port directions.

Properties

General

Used to identify and manage the element itself, including name, annotation, enabled state, and display. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name RING_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether to enable this element true - [true, false]
type Unique type identifier of the element Double Bus Ring Resonator - -
description Brief description of the element Optical double bus ring resonator - -
prefix Prefix for the element name RING - -
local path Local path or working folder of the element - - -

Standard

Defines microring circumference and operating frequency, which determine resonant wavelength and free spectral range.

Name Description Default value Default unit Range
configuration Port configuration bidirectional - [bidirectional, unidirectional]
frequency Frequency 193.1 THz (0, +∞)
length Length 1e-5 m [0, +∞)

Waveguide / Mode 1

Sets transmission parameters of mode 1 (typically TE) in the ring, which determine resonance location, Q factor, and dispersion.

Name Description Default value Default unit Range
orthogonal identifier 1 Orthogonal identifier for mode 1 1 - [1, +∞)
label 1 Label for mode 1 TE - -
loss 1 Loss for mode 1 0 dB/m [0, +∞)
effective index 1 Effective index for mode 1 1 - (-∞, +∞)
group index 1 Group index for mode 1 1 - [0, +∞)
dispersion 1 Dispersion for mode 1 0 s/m/m (-∞, +∞)
dispersion slope 1 Dispersion slope for mode 1 0 s/m^2/m (-∞, +∞)

Waveguide / Mode 1 / Coupler

Sets coupling strengths of the two couplers for mode 1, which determine how strongly light enters and leaves the ring and the drop efficiency.

Name Description Default value Default unit Range
coupling coefficient 1 1 Coupling coefficient for mode 1, coupler 1 0.5 - [0, 1]
coupling coefficient 1 2 Coupling coefficient for mode 1, coupler 2 0.5 - [0, 1]

Waveguide / Mode 1 / Thermal

Sets temperature coefficients for mode 1, which determine thermal tuning of the resonance peak.

Name Description Default value Default unit Range
effective index temperature sensitivity 1 Temperature sensitivity of effective index for mode 1 0 /K (-∞, +∞)
excess loss temperature sensitivity 1 Temperature sensitivity of excess loss for mode 1 0 /K [0, +∞)

Waveguide / Mode 2

Sets transmission parameters of mode 2 (typically TM) in the ring to describe polarization-dependent resonance.

Name Description Default value Default unit Range
orthogonal identifier 2 Orthogonal identifier for mode 2 2 - [1, +∞)
label 2 Label for mode 2 TM - -
loss 2 Loss for mode 2 0 dB/m [0, +∞)
effective index 2 Effective index for mode 2 1 - (-∞, +∞)
group index 2 Group index for mode 2 1 - [0, +∞)
dispersion 2 Dispersion for mode 2 0 s/m/m (-∞, +∞)
dispersion slope 2 Dispersion slope for mode 2 0 s/m^2/m (-∞, +∞)

Waveguide / Mode 2 / Coupler

Sets coupling strengths of the two couplers for mode 2; the role is the same as for mode 1.

Name Description Default value Default unit Range
coupling coefficient 2 1 Coupling coefficient for mode 2, coupler 1 0.5 - [0, 1]
coupling coefficient 2 2 Coupling coefficient for mode 2, coupler 2 0.5 - [0, 1]

Waveguide / Mode 2 / Thermal

Sets temperature coefficients for mode 2; the role is the same as for mode 1.

Name Description Default value Default unit Range
effective index temperature sensitivity 2 Temperature sensitivity of effective index for mode 2 0 /K (-∞, +∞)
excess loss temperature sensitivity 2 Temperature sensitivity of excess loss for mode 2 0 /K [0, +∞)

Thermal

Controls whether thermal effects are enabled for the microring, and sets operating temperature and the heated-length fraction.

Name Description Default value Default unit Range
thermal effects Whether to enable thermal effects false - [true, false]
temperature Temperature %temperature% K (-∞, +∞)
nominal temperature Nominal temperature 300 K (-∞, +∞)
thermal fill factor Fraction of waveguide length affected by thermal effects 1 - [0, 1]

Numerical / Digital Filter

Fits the device frequency-domain response to a digital filter required for time-domain simulation.

Name Description Default value Default unit Range
single tap filter Whether to use a single-tap filter false - [true, false]
number of taps estimation Tap-count estimation method fit tolerance - [disabled, fit tolerance, group delay]
filter fit tolerance Filter fit tolerance 0.001 - (0, 1)
window function Window function rectangular - [rectangular, hamming, hanning]
number of fir taps Number of FIR taps 256 - [1, +∞), power of 2
maximum number of fir taps Upper limit on FIR taps 4096 - [1, +∞), power of 2
filter delay Filter delay 0 s [0, +∞)
initialize filter taps Whether to initialize filter taps false - [true, false]

Diagnostic

Used to check the deviation between the ideal response and the digital-filter fit, confirming frequency-domain accuracy of time-domain simulation. Keep disabled for routine simulations.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)

Results

When run diagnostic is enabled, time-domain sampled simulation produces the following results for response checking:

Results

diagnostic/response

Name Description
transmission Complex transmittance versus frequency for the ideal and fitted responses.
gain Gain (dB) versus frequency for the ideal and fitted responses.
error Relative mean-square error between ideal and fitted amplitudes.

The response index corresponds to a pair of input port, output port, and mode.