Compound Element

Compound Element

COMPOUND

The Compound Element (COMPOUND) is a hierarchical container that can hold other elements. It packages a group of devices into a single symbol and exposes external ports via internal Relays. Beyond structural packaging, it supports custom properties and scripts for parameterized subcircuits, and can carry design-kit version and identity information. It is suitable for organizing reusable modules and managing versions.

Ports

There are no fixed ports. External ports of a compound element are determined by internal Relays: after connecting subcircuit ports to Relays, those ports appear on the compound element.

Properties

General

Used to identify and manage the element itself, including name, annotation, enabled state, and display. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name COMPOUND_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether to enable this element true - [true, false]
type Unique type identifier of the element Compound Element - -
description Brief description of the element Compound is a hierarchical element that contains other elements - -
prefix Prefix for the element name COMPOUND - -
local path Local path or working folder of the element - - -
expandable Whether the compound element interior can be expanded for viewing true - [true, false]

Simulation

Sets simulation parameters inside the compound element; by default these inherit the top-level settings.

Name Description Default value Default unit Range
bitrate Bitrate %bitrate% bits/s (0, +∞)
time window Time window %time window% s (0, +∞)
sample rate Sample rate %sample rate% Hz [0, +∞)
output signal mode Output signal mode %output signal mode% - [sample, block]
number of output signals Number of output signals %number of output signals% - [1, +∞)

Thermal

Sets the operating temperature of the compound element; by default this inherits the top-level temperature.

Name Description Default value Default unit Range
temperature Temperature %temperature% K (-∞, +∞)

Script

Controls when schematic scripts run.

Name Description Default value Default unit Range
run setup script Whether to run the Setup script automatic - [automatic, always]

Validation

Sets pre-simulation checks to catch connection, deadlock, and delay issues early.

Name Description Default value Default unit Range
deadlock resolution Simulation deadlock handling strategy %deadlock resolution% - [ignore, prevent]
delay insertion Port scope for automatic delay insertion %delay insertion% - [output ports, bidirectional ports]
check internal monitors Whether to check monitors inside the compound element true - [true, false]

Numerical

Sets scattering-data analysis options for the compound element.

Name Description Default value Default unit Range
scattering data analysis Whether to enable scattering-data analysis options false - [true, false]
modes Optical mode labels, comma-separated in English, e.g. TE,TM TE - -

Numerical / Digital Filter

Fits the device frequency-domain response to a digital filter required for time-domain simulation.

Name Description Default value Default unit Range
digital filter type Digital filter type FIR - [single tap, FIR, IIR]
number of taps estimation Tap-count estimation method fit tolerance - [disabled, fit tolerance, group delay]
filter fit tolerance Filter fit tolerance 0.05 - (0, 1)
filter fit number of iterations Maximum filter-fit iterations 50 - [1, +∞)
filter fit rolloff Filter fit rolloff 0.05 - [0, 1)
window function Window function rectangular - [rectangular, hamming, hanning]
number of fir taps Number of FIR taps 256 - [1, +∞)
maximum number of fir taps Upper limit on FIR taps 4096 - [1, +∞)
filter delay Filter delay 0 s [0, +∞)
number of iir taps Number of IIR taps 4 - [2, +∞)
maximum number of iir taps Upper limit on IIR taps 20 - [2, +∞)
initialize filter taps Whether to initialize filter taps false - [true, false]

Diagnostic

The compound element is not solved on its own; diagnostics are performed by internal child elements, so this group does not produce results on the compound element.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)
diagnostic data export Whether to export diagnostic data false - [true, false]
diagnostic start frequency Diagnostic start frequency 193.05 THz (0, +∞)
diagnostic stop frequency Diagnostic stop frequency 193.15 THz (0, +∞)
diagnostic data filename Diagnostic data filename sparam.dat - -

Design Kit

Records design-kit and version information to identify the element source and version.

Name Description Default value Default unit Range
version Version number - - -
internal electrical equivalent Whether to use the internal electrical equivalent model %internal electrical equivalent% - [true, false]

Design Kit / Header

Records design-kit header information for recognition by scripts and process design kits.

Name Description Default value Default unit Range
component id Component ID - - -
mcs filename List file of process design kit names and their parameters - - -
mcs Process design kit name - - -

Results

None