Bragg Grating

Bragg Grating

WBG

The Bragg Grating (WBG) models a waveguide Bragg grating: periodic refractive-index modulation strongly reflects selected wavelengths and transmits the rest, forming a wavelength-selective device. The reflection-peak location is set by the grating period (Bragg wavelength); reflectivity and bandwidth are set jointly by coupling strength and grating length. Tapering the coupling strength along the length can suppress side lobes in the reflection spectrum; period chirp can broaden or tilt the reflection spectrum.

Ports

Two bidirectional optical signal ports with the grating between them. The table shows the default configuration.

Name Type Data
port 1 Optical Signal Bidirectional
port 2 Optical Signal Bidirectional

Changing configuration may alter port names or directions.

Properties

General

Used to identify and manage the element itself, including name, annotation, enabled state, and display. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name WBG_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether to enable this element true - [true, false]
type Unique type identifier of the element Bragg Grating - -
description Brief description of the element Waveguide Bragg grating - -
prefix Prefix for the element name WBG - -
local path Local path or working folder of the element - - -

Standard

Defines grating geometry and coupling strength—the primary settings that determine reflection wavelength, reflectivity, and reflection bandwidth.

Name Description Default value Default unit Range
configuration Port configuration bidirectional - [bidirectional, unidirectional]
length Length 0.005 m [0, +∞)
input parameter How grating period or Bragg frequency is specified Bragg frequency - [grating period, Bragg frequency]
period Period 5.3e-7 m [0, +∞)
frequency Bragg wavelength (property name remains frequency; unit is nm) 1550 nm (0, +∞)
coupling parameter Coupling parameter effective index change - [effective index change, coupling coefficient]
effective index change ac AC change in effective index 0.0004 - [0, +∞)
effective index change dc DC change in effective index 0 - [0, +∞)
grating coupling coefficient Grating coupling coefficient 800 1/m (-∞, +∞)
phase shift Phase shift 0 rad (-∞, +∞)

Waveguide / Apodization

Varies coupling strength along the grating length to shape the reflection spectrum and suppress side lobes.

Name Description Default value Default unit Range
apodization function Function type that varies coupling strength along the grating uniform - [uniform, user defined, Gaussian, raised cosine, hyperbolic tangent, sinc]
apodization parameter Parameter of the coupling-strength distribution function 0.5 - (-∞, +∞)
apodization table Data table of normalized length vs. coupling-strength distribution 2×2; columns: normalized length, apodization parameter; first row [0, 1] - -
load apodization from file Whether to load the coupling-strength distribution from a file false - [true, false]
apodization filename Data filename for the coupling-strength distribution apodization.dat - -

Waveguide / Chirp

Varies the period along the grating length to broaden the reflection band and obtain the desired dispersion.

Name Description Default value Default unit Range
chirp function Function type for period variation along length none - [none, user defined, linear chirp parameter, linear chirp coefficient]
chirp parameter Parameter for period variation along length 0 - (-∞, +∞)
chirp coefficient Coefficient for period variation along length 0 - (-∞, +∞)
chirp table Data table of normalized length vs. period variation 2×2; columns: normalized length, chirp coefficient; first row [0, 0] - -
load chirp from file Whether to load period variation from a file false - [true, false]
chirp filename Data filename for period variation chirp.dat - -

Waveguide / Mode 1

Sets transmission parameters of mode 1 (typically TE) in the grating and facet reflection conditions at both ends.

Name Description Default value Default unit Range
orthogonal identifier 1 Orthogonal identifier for mode 1 1 - [1, +∞)
label 1 Label for mode 1 TE - -
loss 1 Loss for mode 1 0 dB/m [0, +∞)
effective index 1 Effective index for mode 1 1.447 - (-∞, +∞)
group index 1 Group index for mode 1 1.447 - [0, +∞)
facet reflectivity left 1 Reflectivity of mode 1 at the left facet 0 - [0, 1]
facet phase left 1 Phase of mode 1 at the left facet 0 rad (-∞, +∞)
facet reflectivity right 1 Reflectivity of mode 1 at the right facet 0 - [0, 1]
facet phase right 1 Phase of mode 1 at the right facet 0 rad (-∞, +∞)

Waveguide / Mode 1 / Thermal

Sets temperature coefficients for mode 1, which determine Bragg-wavelength drift with temperature.

Name Description Default value Default unit Range
effective index temperature sensitivity 1 Temperature sensitivity of effective index for mode 1 0 /K (-∞, +∞)
excess loss temperature sensitivity 1 Temperature sensitivity of excess loss for mode 1 0 /K [0, +∞)

Waveguide / Mode 2

Sets transmission parameters of mode 2 (typically TM) in the grating to describe polarization-dependent reflection.

Name Description Default value Default unit Range
orthogonal identifier 2 Orthogonal identifier for mode 2 2 - [1, +∞)
label 2 Label for mode 2 TM - -
loss 2 Loss for mode 2 0 dB/m [0, +∞)
effective index 2 Effective index for mode 2 1.447 - (-∞, +∞)
group index 2 Group index for mode 2 1.447 - [0, +∞)
facet reflectivity left 2 Reflectivity of mode 2 at the left facet 0 - [0, 1]
facet phase left 2 Phase of mode 2 at the left facet 0 rad (-∞, +∞)
facet reflectivity right 2 Reflectivity of mode 2 at the right facet 0 - [0, 1]
facet phase right 2 Phase of mode 2 at the right facet 0 rad (-∞, +∞)

Waveguide / Mode 2 / Thermal

Sets temperature coefficients for mode 2; the role is the same as for mode 1.

Name Description Default value Default unit Range
effective index temperature sensitivity 2 Temperature sensitivity of effective index for mode 2 0 /K (-∞, +∞)
excess loss temperature sensitivity 2 Temperature sensitivity of excess loss for mode 2 0 /K [0, +∞)

Thermal

Controls whether thermal effects are enabled for the grating, and sets operating temperature and the heated-length fraction.

Name Description Default value Default unit Range
thermal effects Whether to enable thermal effects false - [true, false]
temperature Temperature %temperature% K (-∞, +∞)
nominal temperature Nominal temperature 300 K (-∞, +∞)
thermal fill factor Fraction of waveguide length affected by thermal effects 1 - [0, 1]

Numerical

Sets the number of calculation segments along the device length, which determines spectral calculation accuracy.

Name Description Default value Default unit Range
number of steps Number of steps 50 - [1, +∞)

Numerical / Digital Filter

Fits the device frequency-domain response to a digital filter required for time-domain simulation.

Name Description Default value Default unit Range
digital filter Whether to enable the digital filter false - [true, false]
single tap filter Whether to use a single-tap filter false - [true, false]
number of taps estimation Tap-count estimation method fit tolerance - [disabled, fit tolerance, group delay]
filter fit tolerance Filter fit tolerance 0.001 - (0, 1)
window function Window function rectangular - [rectangular, hamming, hanning]
number of fir taps Number of FIR taps 256 - [1, +∞), power of 2
maximum number of fir taps Upper limit on FIR taps 4096 - [1, +∞), power of 2
filter delay Filter delay 0 s [0, +∞)
initialize filter taps Whether to initialize filter taps false - [true, false]
delay compensation Delay compensation amount 0 - [0, +∞)

Diagnostic

Used to check the deviation between the ideal response and the digital-filter fit, confirming frequency-domain accuracy of time-domain simulation. Keep disabled for routine simulations.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)

Results

When run diagnostic is enabled, time-domain sampled simulation produces the following results:

Results

diagnostic/response

Name Description
transmission Complex transmittance versus frequency for the ideal and fitted responses.
gain Gain (dB) versus frequency for the ideal and fitted responses.
error Relative mean-square error between ideal and fitted amplitudes.

In addition, diagnostic/apodization is written: the apodization envelope along the grating length, with horizontal axes normalized length and length, used to confirm that the coupling-strength distribution matches the design.

The response index corresponds to a pair of input port, output port, and mode.