EME Profile Monitor Setting
EME Profile Monitor Setting #
This section describes the settings of the EME Profile monitor.
In the EME solver, the EME Profile monitor is used to record frequency-domain electromagnetic field data in a specified geometric space.
Select EME Profile in the EME solver tab, click in the Composite viewer, and set relevant parameters in the properties editing interface that automatically pops up to create the EME Profile monitor.
General Setting #
The General tab is about general settings for the EME Profile monitor.

Data Monitoring #
| Name | Description |
|---|---|
| Data Type | Data type of the recorded data, which is Frequency-domain by default; this is a read-only parameter. |
Spatial Sampling #
| Name | Description |
|---|---|
| Per # of dx/dy | Interval at which sampling is performed in the X/Y direction during the simulation process, that is, after how many discretization steps a sampling is conducted. |
Spatial Resolution #
| Name | Description |
|---|---|
| Propagation Direction Resolution | Resolution of the monitor in the propagation direction, which is 100 by default. |
Geometric Dimensions #
Geometry is the tab for setting the geometric dimensions of the EME Profile monitor.

| Name | Description |
|---|---|
| use relative coordinate | Check to select relative coordinates. |
| Spatial Type | Geometry type of the monitor space. |
| X/Y/Z pos | Set center coordinates of the monitor. |
| X/Y/Z span | Set range of the monitor. |
Data Visualizer #
Use the EME Profile monitor to record frequency-domain field datasets. The returned result data includes:
- E: relation between electric field and frequency (wavelength);
- H: relation between magnetic field and frequency (wavelength).
View the frequency-domain field distribution in the Data Visualizer of the EME Profile monitor, with specific operations as shown in the figure below:

Perform operations such as selection, plotting, and saving of data in the data visualization interface. For more details, see Data Visualizer.
For instance, to view the real part of the Ex component, settings and results for Attributes are shown as in the figure below:

Plot a one-dimensional dataset as a 1D line plot: