Traveling Wave Electrode

Traveling Wave Electrode

TW

Traveling Wave Electrode (TW) models a modulator electrode as a microwave transmission line, describing the loss, phase velocity, and impedance matching of the electrical drive signal as it propagates along the electrode. In high-speed modulators, the microwave and optical waves travel in the same direction, and how well their velocities match directly determines device bandwidth. This element is therefore often used to analyze how electrode length, loss, and termination conditions affect the frequency response.

Ports

The electrical signal enters the electrode at input and leaves at output, corresponding to the two ends of the transmission line.

Name Type Data
input Electrical Signal Input
output Electrical Signal Output

Properties

General

Identifies and manages the element itself, including name, annotation, enable state, and display style. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name TW_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether the element is enabled true - [true, false]
type Unique type identifier of the element Traveling Wave Electrode - -
description Brief description of the element Traveling wave electrode transmission line filter - -
prefix Prefix for the element name TW - -
local path Local path or working folder of the element - - -

Standard

Defines electrode length and microwave loss characteristics, which determine the basic shape of the modulation bandwidth and frequency response.

Name Description Default value Default unit Range
length Length 0.01 m [0, +∞)
loss type Loss data source type constant - [constant, linear, square root, table]
microwave loss Microwave loss 0 dB/m [0, +∞)
loss reference frequency Loss reference frequency 1 Hz [0, +∞)
load loss from file Whether to load loss data from a file false - [true, false]
loss filename Loss data file name - - -
loss table Loss data table 1×2; columns: frequency (Hz), loss (dB/m); first row [1, 0] - -

Standard / Source Impedance

Describes the impedance on the signal-source side, which determines the matching condition between the source and the electrode.

Name Description Default value Default unit Range
source impedance type Source impedance data source type constant - [constant, table]
source resistance Source resistance 50 Ohms [0, +∞)
source reactance Source reactance 0 Ohms (-∞, +∞)
load source impedance from file Whether to load source impedance from a file false - [true, false]
source impedance filename Source impedance data file name - - -
source impedance table Source impedance data table 1×3; columns: frequency (Hz), real (Ohms), imag (Ohms); first row [1, 50, 0] - -

Standard / Characteristic Impedance

Describes the transmission-line characteristic impedance, which determines reflection along the line and transmission flatness.

Name Description Default value Default unit Range
characteristic impedance type Characteristic impedance data source type constant - [constant, table]
characteristic resistance Characteristic resistance 50 Ohms [0, +∞)
characteristic reactance Characteristic reactance 0 Ohms (-∞, +∞)
load characteristic impedance from file Whether to load characteristic impedance from a file false - [true, false]
characteristic impedance filename Characteristic impedance data file name - - -
characteristic impedance table Characteristic impedance data table 1×3; columns: frequency (Hz), real (Ohms), imag (Ohms); first row [1, 50, 0] - -

Standard / Terminating Impedance

Describes the termination at the electrode end, which determines reflection strength and frequency-response ripple.

Name Description Default value Default unit Range
terminating impedance type Terminating impedance data source type constant - [constant, table]
terminating resistance Terminating resistance 50 Ohms [0, +∞)
terminating reactance Terminating reactance 0 Ohms (-∞, +∞)
load terminating impedance from file Whether to load terminating impedance from a file false - [true, false]
terminating impedance filename Terminating impedance data file name - - -
terminating impedance table Terminating impedance data table 1×3; columns: frequency (Hz), real (Ohms), imag (Ohms); first row [1, 50, 0] - -

Standard / Junction

Describes the electrical load of the junction region beneath the electrode, which determines modulation efficiency and bandwidth.

Name Description Default value Default unit Range
junction resistance Junction resistance 0 ohm.m [0, +∞)
junction capacitance type Junction capacitance data source type constant - [constant, table]
constant junction capacitance Constant junction capacitance 0 F/m [0, +∞)
load junction capacitance from file Whether to load junction capacitance from a file false - [true, false]
junction capacitance filename Junction capacitance data file name - - -
junction capacitance table Junction capacitance data table 30×2; columns: amplitude (a.u.), capacitance (F/m); first row [-3, 1.86878e-10] - -

Waveguide

Provides the microwave and optical refractive indices used to assess phase-velocity matching between the two.

Name Description Default value Default unit Range
microwave index type Microwave index data source type constant - [constant, table]
microwave index Microwave refractive index 4 - [0, +∞)
load microwave index from file Whether to load the microwave index from a file false - [true, false]
microwave index filename Microwave index data file name - - -
microwave index table Microwave index data table 1×2; columns: frequency (Hz), microwave index; first row [1, 4] - -
optical index Optical refractive index 3 - [0, +∞)

Numerical

Selects how the electrode response is described, determining whether results are presented as modulation efficiency or drive voltage.

Name Description Default value Default unit Range
transfer function Transfer function modulation reduction factor - [modulation reduction factor, modulation voltage]

Numerical / Digital Filter

Fits the device frequency-domain response to a digital filter required for time-domain simulation.

Name Description Default value Default unit Range
time variant digital filter Update method for the time-varying digital filter interpolate - [interpolate, update]
single tap filter Whether to use a single-tap filter false - [true, false]
number of taps estimation Tap-count estimation method fit tolerance - [disabled, fit tolerance, group delay]
filter fit tolerance Filter fit tolerance 0.001 - (0, 1)
window function Window function rectangular - [rectangular, hamming, hanning]
number of fir taps Number of FIR taps 256 - [1, +∞)
maximum number of fir taps Upper limit on the number of FIR taps 4096 - [1, +∞)
filter delay Filter delay 0 s [0, +∞)
initialize filter taps Whether to initialize filter taps false - [true, false]

Diagnostic

Used to check the deviation between the ideal response and the digital-filter fit, confirming the frequency-domain accuracy of time-domain simulation. Keep disabled for routine simulations.

Name Description Default value Default unit Range
run diagnostic Whether to run diagnostics false - [true, false]
diagnostic size Number of diagnostic data points or buffer size 1024 - [2, +∞)
stop frequency Stop frequency 5e10 Hz (0, +∞)

Results

When run diagnostic is enabled, time-domain sample-mode simulation produces the following results for verifying the response:

Results

diagnostic/response

Name Description
transmission Complex transmittance versus frequency for the ideal and fitted responses.
gain Gain (dB) versus frequency for the ideal and fitted responses.
error Relative mean-square error between the ideal and fitted magnitudes.

In addition, diagnostic/normalized average voltage is also written: the variation of the average modulation voltage on the electrode with frequency, which can be used to examine the frequency response of the transmission line model itself.