Spectrum Analyzer

Spectrum Analyzer

RFSA

Spectrum Analyzer (RFSA) measures the power distribution of an electrical signal versus frequency and produces an electrical-domain spectrum. It is suited to observing the harmonic structure of drive signals, filter passbands and stopbands, link noise floor, and various spurious components. Analysis bandwidth, resolution bandwidth, and display mode are configurable, and time-varying spectra can also be obtained.

Ports

A single electrical-signal analysis input port that receives the signal under measurement.

Name Type Data
input Electrical Signal Analyzer Input

Properties

General

Identifies and manages the element itself, including name, annotation, enable state, and display style. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name RFSA_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether the element is enabled true - [true, false]
type Unique type identifier of the element Spectrum Analyzer - -
description Brief description of the element Measures the magnitude of an input signal versus frequency - -
prefix Prefix for the element name RFSA - -
local path Local path or working folder of the element - - -
icon type Icon type small - [small, medium]

Standard

Sets analysis bandwidth, resolution, and display mode, which determine the observation range and resolution of the spectrum.

Name Description Default value Default unit Range
limit frequency range Whether to enable frequency-range limiting false - [true, false]
frequency range Frequency range (bandwidth) 1 THz (0, +∞)
plot format Plot format power - [rectangular, power]
power unit Power unit dBm - [W, dBm, W/Hz, dBm/Hz]
reference level Reference level 0 dBm (-∞, +∞)
remove dc Whether to remove the DC component false - [true, false]
sensitivity Sensitivity (minimum measurable signal level) -100 dBm (-∞, +∞)
resolution Resolution disable - [disable, rectangular function, Gaussian function]
bandwidth Bandwidth 10 GHz [0, +∞)
limit time range Whether to enable time-range settings false - [true, false]
start time Start time 0 s [0, +∞)
stop time Stop time 1 s [0, +∞)

Enhanced

Configures the spectrogram used to observe how the spectrum evolves over time.

Name Description Default value Default unit Range
spectrogram Whether to compute the spectrogram disable - [disable, waterfall, average]
spectrogram window function Spectrogram window function rectangular - [rectangular, hamming, hanning, blackman]
spectrogram time window Spectrogram time window %time window%/20 s (spectrogram time overlap, +∞)
spectrogram time overlap Spectrogram time overlap %time window%/30 s [0, spectrogram time window)

Simulation

Sets how signals are generated and output. By default these inherit the top-level simulation settings and generally need not be changed.

Name Description Default value Default unit Range
input signal selection Input signal selection method last - [last, index]
input signal index Input signal index 1 - [1, +∞)
include delays Whether to insert delays false - [true, false]

Display

Controls result refresh and display buffering. Affects viewing only and does not change computed results.

Name Description Default value Default unit Range
refresh Whether to refresh the display true - [true, false]
refresh length Refresh length 1024 - [0, +∞)
limit display memory Whether to limit display memory length true - [true, false]
display memory length Display memory length 2048 - [2, +∞)

Results

After simulation completes, the Result panel shows the spectrum of the input signal:

Results

Name Description
signal Spectrum of the input electrical signal. When plot format is rectangular, this curve is the amplitude spectrum.
spectrogram Time-varying spectrum. Written when spectrogram is waterfall or average and plot format is not rectangular; not present when set to disable or when the plot is rectangular.