Spectrum Analyzer
Spectrum Analyzer #
![]()
Spectrum Analyzer (RFSA) measures the power distribution of an electrical signal versus frequency and produces an electrical-domain spectrum. It is suited to observing the harmonic structure of drive signals, filter passbands and stopbands, link noise floor, and various spurious components. Analysis bandwidth, resolution bandwidth, and display mode are configurable, and time-varying spectra can also be obtained.
Ports #
A single electrical-signal analysis input port that receives the signal under measurement.
| Name | Type | Data |
|---|---|---|
| input | Electrical Signal | Analyzer Input |
Properties #
General #
Identifies and manages the element itself, including name, annotation, enable state, and display style. This property group affects schematic presentation only and does not change device behavior.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| name | Element name | RFSA_1 | - | - |
| annotate | Whether to show annotation | true | - | [true, false] |
| enabled | Whether the element is enabled | true | - | [true, false] |
| type | Unique type identifier of the element | Spectrum Analyzer | - | - |
| description | Brief description of the element | Measures the magnitude of an input signal versus frequency | - | - |
| prefix | Prefix for the element name | RFSA | - | - |
| local path | Local path or working folder of the element | - | - | - |
| icon type | Icon type | small | - | [small, medium] |
Standard #
Sets analysis bandwidth, resolution, and display mode, which determine the observation range and resolution of the spectrum.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| limit frequency range | Whether to enable frequency-range limiting | false | - | [true, false] |
| frequency range | Frequency range (bandwidth) | 1 | THz | (0, +∞) |
| plot format | Plot format | power | - | [rectangular, power] |
| power unit | Power unit | dBm | - | [W, dBm, W/Hz, dBm/Hz] |
| reference level | Reference level | 0 | dBm | (-∞, +∞) |
| remove dc | Whether to remove the DC component | false | - | [true, false] |
| sensitivity | Sensitivity (minimum measurable signal level) | -100 | dBm | (-∞, +∞) |
| resolution | Resolution | disable | - | [disable, rectangular function, Gaussian function] |
| bandwidth | Bandwidth | 10 | GHz | [0, +∞) |
| limit time range | Whether to enable time-range settings | false | - | [true, false] |
| start time | Start time | 0 | s | [0, +∞) |
| stop time | Stop time | 1 | s | [0, +∞) |
Enhanced #
Configures the spectrogram used to observe how the spectrum evolves over time.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| spectrogram | Whether to compute the spectrogram | disable | - | [disable, waterfall, average] |
| spectrogram window function | Spectrogram window function | rectangular | - | [rectangular, hamming, hanning, blackman] |
| spectrogram time window | Spectrogram time window | %time window%/20 |
s | (spectrogram time overlap, +∞) |
| spectrogram time overlap | Spectrogram time overlap | %time window%/30 |
s | [0, spectrogram time window) |
Simulation #
Sets how signals are generated and output. By default these inherit the top-level simulation settings and generally need not be changed.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| input signal selection | Input signal selection method | last | - | [last, index] |
| input signal index | Input signal index | 1 | - | [1, +∞) |
| include delays | Whether to insert delays | false | - | [true, false] |
Display #
Controls result refresh and display buffering. Affects viewing only and does not change computed results.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| refresh | Whether to refresh the display | true | - | [true, false] |
| refresh length | Refresh length | 1024 | - | [0, +∞) |
| limit display memory | Whether to limit display memory length | true | - | [true, false] |
| display memory length | Display memory length | 2048 | - | [2, +∞) |
Results #
After simulation completes, the Result panel shows the spectrum of the input signal:
![]()
| Name | Description |
|---|---|
| signal | Spectrum of the input electrical signal. When plot format is rectangular, this curve is the amplitude spectrum. |
| spectrogram | Time-varying spectrum. Written when spectrogram is waterfall or average and plot format is not rectangular; not present when set to disable or when the plot is rectangular. |