Oscilloscope

Oscilloscope

OSC

Oscilloscope (OSC) displays electrical signal waveforms in the time domain for observing drive waveforms, filter outputs, photodetector electrical signals, and pulse and logic source sequences. The time axis follows the global sample rate and time window and directly reflects the actual waveforms in the simulation.

Ports

A single electrical signal analyzer input port that receives the signal under observation.

Name Type Data
input Electrical Signal Analyzer Input

Properties

General

Used to identify and manage the element itself, including name, annotation, enable state, and display options. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name OSC_1 - -
annotate Whether to display the annotation true - [true, false]
enabled Whether to enable this element true - [true, false]
type Unique type identifier of the element Oscilloscope - -
description Brief description of the element Allows observation of constantly varying signals in time domain - -
prefix Prefix for the element name OSC - -
local path Local path or working folder of the element - - -
icon type Icon type small - [small, medium]

Standard

Sets the waveform display range, which determines the observation time span and amplitude lower bound.

Name Description Default value Default unit Range
minimum amplitude Minimum amplitude 0 - [0, +∞)
limit time range Whether to enable the time range setting false - [true, false]
start time Start time 0 s [0, +∞)
stop time Stop time 1 s [0, +∞)

Simulation

Sets how signals are generated and output. By default inherits top-level simulation settings; usually no modification is needed.

Name Description Default value Default unit Range
input signal selection Input signal selection method last - [last, index]
input signal index Input signal index 1 - [1, +∞)
include delays Whether to insert delays false - [true, false]

Display

Controls result refresh and display buffering. Affects viewing only and does not change computed results.

Name Description Default value Default unit Range
refresh Whether to refresh the display true - [true, false]
refresh length Refresh length 1024 - [0, +∞)
limit display memory Whether to limit display memory length true - [true, false]
display memory length Display memory length 2048 - [2, +∞)

Results

After simulation completes, the Result panel shows a set of time-domain waveforms:

Results

Name Description
signal Time-domain waveform of the input electrical signal.