Optical Spectrum Analyzer
Optical Spectrum Analyzer #
![]()
Optical Spectrum Analyzer (OSA) measures optical signal power versus frequency or wavelength and presents the spectrum. It can show laser spectral lines and linewidth, sideband structure from modulation, and noise and crosstalk components at other wavelengths in the link. Observation bandwidth, resolution bandwidth, and horizontal-axis type are configurable; a time-varying spectrum can also be obtained.
Ports #
A single optical signal analyzer input port that receives the optical signal under measurement.
| Name | Type | Data |
|---|---|---|
| input | Optical Signal | Analyzer Input |
Properties #
General #
Used to identify and manage the element itself, including name, annotation, enable state, and display options. This property group affects schematic presentation only and does not change device behavior.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| name | Element name | OSA_1 | - | - |
| annotate | Whether to display the annotation | true | - | [true, false] |
| enabled | Whether to enable this element | true | - | [true, false] |
| type | Unique type identifier of the element | Optical Spectrum Analyzer | - | - |
| description | Brief description of the element | Measures the magnitude of an input optical signal versus frequency | - | - |
| prefix | Prefix for the element name | OSA | - | - |
| local path | Local path or working folder of the element | - | - | - |
| icon type | Icon type | small | - | [small, medium] |
Standard #
Sets scan range, resolution, and display mode, which determine the observation bandwidth and resolution of the spectrum.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| limit frequency range | Whether to enable the frequency range limit | false | - | [true, false] |
| start frequency | Start frequency | 190 | THz | (0, +∞) |
| stop frequency | Stop frequency | 200 | THz | (0, +∞) |
| plot kind | Plot horizontal-axis type | frequency | - | [frequency, wavelength] |
| plot format | Plot format | power | - | [rectangular, power] |
| power unit | Power unit | dBm | - | [W, dBm, W/Hz, dBm/Hz] |
| reference level | Reference level | 0 | dBm | (-∞, +∞) |
| sensitivity | Sensitivity (minimum measurable signal level) | -100 | dBm | (-∞, +∞) |
| resolution | Resolution | disable | - | [disable, rectangular function, Gaussian function] |
| bandwidth | Bandwidth | 10 | GHz | [0, +∞) |
| limit time range | Whether to enable the time range setting | false | - | [true, false] |
| start time | Start time | 0 | s | [0, +∞) |
| stop time | Stop time | 1 | s | [0, +∞) |
| window function | Window function | rectangular | - | [rectangular, hamming, hanning, blackman] |
Enhanced #
Sets the time-varying spectrogram for observing spectral evolution over time.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| spectrogram | Whether to compute the spectrogram | disable | - | [disable, waterfall, average] |
| spectrogram window function | Spectrogram window function | rectangular | - | [rectangular, hamming, hanning, blackman] |
| spectrogram time window | Spectrogram time window | %time window%/20 |
s | (spectrogram time overlap, +∞) |
| spectrogram time overlap | Spectrogram time overlap | %time window%/30 |
s | [0, spectrogram time window) |
Simulation #
Sets how signals are generated and output. By default inherits top-level simulation settings; usually no modification is needed.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| input signal selection | Input signal selection method | last | - | [last, index] |
| input signal index | Input signal index | 1 | - | [1, +∞) |
| include delays | Whether to insert delays | false | - | [true, false] |
Display #
Controls result refresh and display buffering. Affects viewing only and does not change computed results.
| Name | Description | Default value | Default unit | Range |
|---|---|---|---|---|
| refresh | Whether to refresh the display | true | - | [true, false] |
| refresh length | Refresh length | 1024 | - | [0, +∞) |
| limit display memory | Whether to limit display memory length | true | - | [true, false] |
| display memory length | Display memory length | 2048 | - | [2, +∞) |
Results #
After simulation completes, the Result panel shows a set of spectral results by input port and optical mode. The figure below is an example:
![]()
| Name | Description |
|---|---|
| sum/signal | Spectrum summed over all optical modes. Written when plot format is power. |
| mode N/signal | Spectrum of a single optical mode. N starts from 1. Written for both power and rectangular. |
| sum/spectrogram | Time-varying spectrum. Written when spectrogram is waterfall or average and plot format is not rectangular. |