Optical Modulator Measured

Optical Modulator Measured

OM

Optical Modulator Measured (OM) modulates an optical carrier with an electrical signal. Its electro-optic response is given by a measured data table or polynomial coefficients rather than an analytical model. It is suitable for building modulator models close to real devices from measured absorption, phase, or effective-index versus voltage characteristics, and for comparing modulation behavior and linearity at different bias points.

Ports

modulation receives the electrical drive signal; the two optical ports are configured as input/output according to configuration.

Name Type Data
port 1 Optical Signal Bidirectional
modulation Electrical Signal Input
port 2 Optical Signal Bidirectional

The table shows the default bidirectional configuration; after changing configuration, the port directions may change.

Properties

General

Used to identify and manage the element itself, including name, annotation, enabled state, and display. This group of properties only affects schematic presentation and does not change device behavior.

Name Description Default value Default unit Range
name Element name OM_1 - -
annotate Whether to show annotation true - [true, false]
enabled Whether the element is enabled true - [true, false]
type Unique type identifier of the element Optical Modulator Measured - -
description Brief description of the element modulates an optical signal depending on electrical signal - -
prefix Prefix for the element name OM - -
local path Local path or working folder of the element - - -

Standard

Defines the modulator operating conditions and how the electro-optic response is described; these are the primary settings that determine modulation behavior.

Name Description Default value Default unit Range
configuration Port configuration bidirectional - [bidirectional, unidirectional]
frequency Frequency 193.1 THz (0, +∞)
length Length 1 m [0, +∞)
input parameter Parameter input method table - [table, coefficients]

Standard / Table

Describes the electro-optic response with a measured data table, suitable when measured characteristic curves are used directly.

Name Description Default value Default unit Range
load from file Whether to load data from a file false - [true, false]
measurement filename Measurement data file name - - -
measurement type Measurement type effective index - [absorption & phase, effective index]
measurement Measurement data table 11×3; columns: amplitude (a.u.), effective index (real), effective index (imag); first row [-5, 1.40392e-6, 1.14823e-7] - -

Standard / Coefficients

Describes the electro-optic response with polynomial coefficients, suitable when fitted results are already known.

Name Description Default value Default unit Range
absorption coefficient a Absorption coefficient a -0.0617 dB/V^3/m (-∞, +∞)
absorption coefficient b Absorption coefficient b -0.2804 dB/V^2/m (-∞, +∞)
absorption coefficient c Absorption coefficient c -0.6635 dB/V/m (-∞, +∞)
absorption coefficient d Absorption coefficient d -0.0719 dB/m (-∞, +∞)
phase coefficient a Phase coefficient a -0.0038 rad/V^3/m (-∞, +∞)
phase coefficient b Phase coefficient b 0.1132 rad/V^2/m (-∞, +∞)
phase coefficient c Phase coefficient c -0.4825 rad/V/m (-∞, +∞)
phase coefficient d Phase coefficient d -0.0107 rad/m (-∞, +∞)

Enhanced

Describes electrode and microwave characteristics that determine phase-velocity matching and impedance matching under high-speed modulation.

Name Description Default value Default unit Range
electrode type Electrode type lumped - [lumped, traveling wave]
microwave loss Microwave loss 0 dB/m [0, +∞)
microwave index Microwave refractive index 3 - [0, +∞)
optical index Optical refractive index 3 - [0, +∞)
impedance mismatch How impedance mismatch is handled false - [true, false]
source impedance Source impedance 50 Ohms [0, +∞)
characteristic impedance Characteristic impedance 50 Ohms [0, +∞)
terminating impedance Terminating impedance 50 Ohms [0, +∞)

Waveguide

Lists the optical modes supported by this element for interfacing with connected waveguides and devices.

Name Description Default value Default unit Range
modes Optical mode labels, separated by English commas, e.g. TE,TM TE,TM - -

Numerical

Sets the number of computation segments along the device length, which determines accuracy for long devices and strong dispersion.

Name Description Default value Default unit Range
number of steps Number of steps 30 - [2, +∞)

Results

None