Eye Diagram

Eye Diagram

EYE

Eye Diagram (EYE) folds the received waveform by bit period to form an eye diagram. The degree of eye opening and the thickness of the traces directly reflect intersymbol interference, noise, and jitter. In addition to the graphical display, it can report eye height, eye width, Q factor, extinction ratio, jitter, and BER estimates for evaluating link error-rate margin.

Ports

input is the signal under test; reference is the reference input used for clock recovery. Both are electrical signal analyzer inputs.

The bit pattern port exists only when the bit pattern input property is enabled; by default it is not present.

Name Type Data
bit pattern Digital Signal Analyzer Input
reference Electrical Signal Analyzer Input
input Electrical Signal Analyzer Input

Properties

General

Used to identify and manage the element itself, including name, annotation, enable state, and display options. This property group affects schematic presentation only and does not change device behavior.

Name Description Default value Default unit Range
name Element name EYE_1 - -
annotate Whether to display the annotation true - [true, false]
enabled Whether to enable this element true - [true, false]
type Unique type identifier of the element Eye Diagram - -
description Brief description of the element Allows observation and analysis of eye diagrams - -
prefix Prefix for the element name EYE - -
local path Local path or working folder of the element - - -
icon type Icon type small - [small, medium]

Standard

Sets the eye folding window and clock alignment, which determine the display range and trace stability.

Name Description Default value Default unit Range
bit pattern input Bit pattern input selection false - [true, false]
bitrate Bit rate %bitrate% bits/s [1, +∞)
signal reference input Signal reference input true - [true, false]
eye period Eye period (typically in bit periods) 1.5 bit period [1, +∞)
ignore start periods Number of periods to ignore at the start 8 - [0, +∞)
ignore end periods Number of periods to ignore at the end 8 - [0, +∞)
clock recovery Clock recovery method automatic - [automatic, user defined]
synchronization delay Synchronization delay 0 s -
limit time range Whether to enable the time range setting false - [true, false]
start time Start time 0 s [0, +∞)
stop time Stop time 1 s [0, +∞)

Enhanced

Sets eye display style and decision analysis options, which determine the output graphics and measurement results.

Name Description Default value Default unit Range
color grading Whether to enable eye color grading display true - [true, false]
binning size Number of bins in the eye histogram 500 - [0, +∞)
smoothness Smoothness 10 - [0, +∞)
random sampling Whether to use random sampling false - [true, false]
time unit Time unit s - [s, bit period]
number of levels Number of signal levels (e.g., PAM level count) 2 - [2, +∞)
decision point Decision point selection method automatic - [automatic, user defined]
decision instant Decision instant 2e-11 s -
threshold Threshold 1×1; columns: amplitude (a.u.); first row [0.5] - -
BER estimation Bit error rate (BER) estimation method Gaussian - [Gaussian, measured]
calculate measurements Whether to calculate measurement results false - [true, false]
calculate graphs Whether to calculate graph results false - [true, false]
eye opening tolerance Eye opening tolerance 0 ratio [0, 1]
plot waveforms Whether to plot waveforms false - [true, false]
minimum amplitude Minimum amplitude 0 - [0, +∞)

Simulation

Sets how signals are generated and output. By default inherits top-level simulation settings; usually no modification is needed.

Name Description Default value Default unit Range
input signal selection Input signal selection method last - [last, index]
input signal index Input signal index 1 - [1, +∞)
include delays Whether to insert delays false - [true, false]

Display

Controls result refresh and display buffering. Affects viewing only and does not change computed results.

Name Description Default value Default unit Range
refresh Whether to refresh the display true - [true, false]
refresh length Refresh length 8192 - [0, +∞)
limit display memory Whether to limit display memory length true - [true, false]
display memory length Display memory length 2048 - [2, +∞)

Results

After simulation completes, the Result panel shows the eye diagram along with associated waveforms, curves, and measurements. The figure below is an example for one input port:

Results

eye diagram

Name Description
eye diagram Eye diagram (amplitude–time) obtained by folding the input waveform by bit period.

measurement

Name Description
decision instant Decision instant used for eye measurements.
threshold Decision threshold used for eye measurements.
BER Bit error rate estimated at the decision point.
Q factor Q factor estimated at the decision point.
height Eye height.
amplitude Eye amplitude.
extinction ratio Extinction ratio.
width Eye width.
jitter RMS RMS jitter.
opening factor Eye opening factor.
pulse width Pulse width.
peak to peak jitter Peak-to-peak jitter.

graph

Name Description
threshold at min BER Decision threshold that minimizes BER, swept along the decision instant.
min BER Minimum BER at each decision instant.
min log of BER Logarithm of the minimum BER.
Q factor Q factor at each decision instant.
level zero mean Mean of the low level.
level zero sigma Standard deviation of the low level.
level one mean Mean of the high level.
level one sigma Standard deviation of the high level.
height Eye height versus decision instant.
amplitude Eye amplitude versus decision instant.
extinction ratio Extinction ratio versus decision instant.
opening factor Eye opening factor versus decision instant.

waveform

Name Description
reference Reference signal waveform used for clock recovery.
correlation Correlation result between the input and reference waveforms.
input Input signal waveform after clock recovery.
bit pattern Digital bit pattern obtained from decision.